-
GD6100D Insulation Oil Tan Delta Tester
In the preventive test of electrical equipment insulation, periodic measurement of insulating oil parameters of electrical equipment is required. The measurement of dielectric loss and resistivity of insulating oil is one of the most important items. For a long time, most of them have been measured by the bridge method, which is cumbersome to operate, and the measurement accuracy is affected by many factors, resulting in large measurement errors.?
-
GDB-H Handheld Automatic Transformer Turns Ratio Tester
It can accurately measure turns ratio, group and phase angle, which is suitable for all kinds of transformers such as Z type transformers, rectifier transformers, electric furnace transformers, phase-shifting transformers, traction transformers, scott and invert-scott transformers.
-
GDB-II Transformer Turns Ratio Tester
According to IEC and relevant national standards, the transformer ratio test is a must-do item during the production, user handover, and overhaul test of power transformers. This can effectively supervise the quality of the transformer products during delivery and use, and prevent short circuits, open circuit, wrong connection between transformer turns, and internal failure or contact failure of the regulator switch.
For this reason, the ratio tester GDB-II developed and produced by our company makes the operation easier, complete functions, stable and reliable data, and greatly improves the test speed according to the user’s on-site use requirements on the original basis. It meets the needs of various large, medium, and small oil transformer ratio tests.
-
GD6800 Capacitance and Dissipation Factor Tester
GD6800 is a fully automatic 10kV insulation power factor/dissipation factor (tan?) tester?designed for condition assessment of electrical insulation in high voltage apparatus such as transformers, bushings, circuit breakers, cables, lightning arresters and rotating machinery.
?
-
GDOT-3B 100kV Three Cups Insulation Oil Breakdown Voltage (BDV) Tester
In?the?power?system?and?factories,?mines,?enterprises?have?a?large?number of?electrical?equipment,?its?internal?insulation?are?oil-filled?insulation.?The dielectric?strength?test?of?the?insulating?oil?is?a?routine?test?must?be?measured.
In?order?to?adapt?to?the?needs?of?the?rapid?development?of?the?power industry,?the?new?version GDOT-3B Insulation oil?BDV?tester increase?the?standards?and?methods?of?selection?and?other?content,?simplify the user’s operation, to facilitate the application of the user for different conditions?of?use.?This?product?is?based?on?the?new?test?protocol?DL/T?596-2005 and the corresponding national standard GB/T 507-2002 and DL/T 429.9-91 design and manufacture, the use of micro-single-chip computer control, electromechanical integration of all automation, high measurement accuracy, greatly improving the efficiency of the work, but also greatly reduces the staff’s labor intensity.
?
-
GDKC-5000 Transformer On Load Tap Changer Tester
GDKC-5000 Transformer On Load Tap Changer Tester can accurately measure the transient time, transient waveform, transient resistance, three-phase synchronization and other parameters of the load tap changer. It is an ideal device for testing load tap changer. It meets the requirements of checking the action sequence of load tap changer and measuring of switching time.
-
GDB-IV Three Phase Transformer Turns Ratio Tester
The internal power module in the tester generates the three-phase power or two-phase power, which is output to the high voltage side of the transformer. Then the high voltage and low voltage are sampled at the same time. Finally, the group, ratio, error,?and phase difference are calculated.
-
GD6900 Capacitance and Dissipation Factor Tester
GD6900 measures the capacitance and dielectric loss factor (tgδ) of high voltage electric equipment. It is integrated structure, built-in dielectric loss test bridge, variable frequency adjustable power supply, boosting transformer and SF6 standard capacitor.
-
GDOT-3C 80kV 3 Cups Insulation Oil Breakdown Voltage (BDV)Tester
GDOT-3C 80kV 3 Cups Insulation Oil Breakdown Voltage Tester is fully digital industrial instrument with microcomputer control. It has the features of high accuracy and strong anti-interference ability.
-
GDB-P Auto Transformer Turns Ratio Tester
According to IEC and the relevant national standards, transformer turns ratio test is a necessary project in the process of power transformer production, user handover and maintenance test.
-
GDZRS-20B Three Phase DC Winding Resistance Tester
GDZRS-20B?Three Phase DC Winding Resistance Tester?is a new generation of rapid tester that integrates magnetization method testing, three-phase testing (Yn, Y, △) and degaussing functions. It is an ideal equipment for measuring the DC resistance of large power transformers. The screen adopts a large-screen high-resolution LCD, which is convenient for on-site use. All direct resistance test items can be completed with one connection. The test speed is fast, the accuracy is high, and the measuring range is wide.
-
GDZRC Series DC Winding Resistance Tester (GDZRC-10A)
GDZRC-10A
GDZRC series DC winding resistance tester?is designed to measure DC resistance of inductive?devices, such as transformers and power inductors.
It has the features of fast measurement, small size?and high accuracy of measurement,which is ideal equipment?of measuring transformer winding and DC resistance of?big power inductance equipment.